Aerial Cable with Rated Voltage 10KV or 35KV

Inquire now

Aerial Cable with Rated Voltage 10KV or 35KV

Click to enlarge image

 Model Number JKYJ

Model and application

Model

Name

Usage

JKYJ

Copper conductor XLPE insulated aerial cable

Used for fixed installation.
Soft copper cable is used for the leading wires of transformer.

Cable should keep some distance from trees when it is being laid, and it can touch the trees frequently when it is on operation.

JKTRYJ

Soft copper conductor XLPE insulated aerial cable

JKLYJ

Aluminum conductor XLPE insulated aerial cable

JKY

Copper conductor PE insulated aerial cable

JKTRY

Soft copper conductor PE insulated aerial cable

JKLY

Aluminum conductor PE insulated aerial cable

JKLYJ/Q

Aluminum conductor thin XLPE insulated light aerial cable

Used for fixed installation.

Cables should keep some distance from trees when they are being laid, but they can only couch the trees for a short time when on operation.

JKLY/Q

Aluminum conductor thin PE insulated light aerial cable

 

Standards of products

They are manufactured according to GB/T14049, Aerial Cable with rated voltage 10KV and 35KV.

 

Features

1.     The rated voltages are 10(12) kilovolts and 35(42) kilovolts. These cables can be used in the system where the single phase earthed fault normally less than 1 minute each time of the system of maximum duration less than 8 hours each time, but the total duration not more than 125 hours.

2.     Ambient temperature should be not lower than -20 when a cable is installed.

3.     Maximum temperature is 250 when a cable is shorted for less than 5 seconds for XLPE insulated cable.

4.     Minimum bending radius is as follows when cables are installed:
for single: core cable-20(D+d),mm
for multi: cores cable-15(D+d),mm

Note:D denotes the overall diameter of cable, while d means the diameter of conductor, unit: millimeter.

 

Models and sizes


Model


Number of cores

Rated voltage(KV)

10

35

Nominal cross-section(square millimeter)

JKYJ

1

10300

50300

JKTRYJ

3

25300

-

JKLYJ

JKY

1

10300

-

JKTRY

JKLY

JKLYJ/Q

JKLY/Q

 